HIPAA Compliance Checklist (Security Rule)

A HIPAA Security Rule checklist that lists every standard and implementation specification in 45 CFR 164.308 to 164.316, marked required or addressable exactly as the regulation does, with a free editable Word file for MSPs and their healthcare clients.

By Reviewed 20 November 2026For MSPs and MSSPs supporting healthcare clients, vCISOs acting as security official for a covered entity or business associate, Practice managers preparing for a HIPAA review

What this checklist covers

This checklist covers the HIPAA Security Rule: the part of HIPAA that sets out how covered entities and business associates protect electronic protected health information (ePHI). It lists every standard and implementation specification in 45 CFR 164.308 (administrative), 164.310 (physical), 164.312 (technical), the business associate contract requirements in 164.308(b) and 164.314, and the documentation rules in 164.316, using the wording and the required or addressable label from the regulation text on eCFR, read on 20 November 2026.

It does not cover the Privacy Rule or the Breach Notification Rule, which have their own requirements. It is a working list for planning and evidence, not legal advice, and it does not replace the risk analysis the Security Rule requires.

If you only want the file, download the HIPAA compliance checklist in Word. It opens in Microsoft Word, Google Docs and LibreOffice.

Who it applies to

The Security Rule applies to covered entities (health plans, healthcare clearinghouses and healthcare providers that carry out standard electronic transactions) and to their business associates. An MSP that hosts, manages or can access a client’s ePHI is usually a business associate and has its own obligations under the rule, not just contractual ones. The checklist works for both sides: use it for a client’s programme and for your own.

There is no official HIPAA certification. Checklists, assessments and third-party reports can show how a programme is working, but compliance is judged against the regulation itself.

Required versus addressable

Every implementation specification in the Security Rule is marked “Required” or “Addressable” (164.306(d)). Addressable is not the same as optional:

  • Required: implement it.
  • Addressable: assess whether it is a reasonable and appropriate safeguard in your environment. If it is, implement it. If it is not, document why and implement an equivalent alternative measure if that is reasonable and appropriate.

Some standards, such as assigned security responsibility and audit controls, have no separate implementation specifications. The standard itself must be met (164.306(c)). They appear in the tables as “Standard”.

When choosing security measures, the rule lets you take into account your size, complexity and capabilities, your technical infrastructure, the cost of the measures and the probability and criticality of potential risks to ePHI (164.306(b)). That is why the same checklist item can look different at a three-person clinic and at a hospital group.

Administrative safeguards (45 CFR 164.308)

Specification Reference Status
Risk analysis 164.308(a)(1)(ii)(A) Required
Risk management 164.308(a)(1)(ii)(B) Required
Sanction policy 164.308(a)(1)(ii)(C) Required
Information system activity review 164.308(a)(1)(ii)(D) Required
Assigned security responsibility (named security official) 164.308(a)(2) Standard
Authorization and/or supervision 164.308(a)(3)(ii)(A) Addressable
Workforce clearance procedure 164.308(a)(3)(ii)(B) Addressable
Termination procedures 164.308(a)(3)(ii)(C) Addressable
Isolating health care clearinghouse functions 164.308(a)(4)(ii)(A) Required
Access authorization 164.308(a)(4)(ii)(B) Addressable
Access establishment and modification 164.308(a)(4)(ii)(C) Addressable
Security reminders 164.308(a)(5)(ii)(A) Addressable
Protection from malicious software 164.308(a)(5)(ii)(B) Addressable
Log-in monitoring 164.308(a)(5)(ii)(C) Addressable
Password management 164.308(a)(5)(ii)(D) Addressable
Response and reporting (security incidents) 164.308(a)(6)(ii) Required
Data backup plan 164.308(a)(7)(ii)(A) Required
Disaster recovery plan 164.308(a)(7)(ii)(B) Required
Emergency mode operation plan 164.308(a)(7)(ii)(C) Required
Testing and revision procedures 164.308(a)(7)(ii)(D) Addressable
Applications and data criticality analysis 164.308(a)(7)(ii)(E) Addressable
Evaluation (periodic technical and nontechnical) 164.308(a)(8) Standard

The security awareness and training standard (164.308(a)(5)) applies to all members of the workforce, including management. The isolating clearinghouse specification only applies where a healthcare clearinghouse is part of a larger organisation.

Physical safeguards (45 CFR 164.310)

Specification Reference Status
Contingency operations 164.310(a)(2)(i) Addressable
Facility security plan 164.310(a)(2)(ii) Addressable
Access control and validation procedures 164.310(a)(2)(iii) Addressable
Maintenance records 164.310(a)(2)(iv) Addressable
Workstation use 164.310(b) Standard
Workstation security 164.310(c) Standard
Disposal 164.310(d)(2)(i) Required
Media re-use 164.310(d)(2)(ii) Required
Accountability (record of hardware and media movements) 164.310(d)(2)(iii) Addressable
Data backup and storage (before moving equipment) 164.310(d)(2)(iv) Addressable

For a business with no premises of its own, the facility items still apply to wherever its systems are housed, which often means confirming what a hosting or cloud provider does and recording it.

Technical safeguards (45 CFR 164.312)

Specification Reference Status
Unique user identification 164.312(a)(2)(i) Required
Emergency access procedure 164.312(a)(2)(ii) Required
Automatic logoff 164.312(a)(2)(iii) Addressable
Encryption and decryption (data at rest) 164.312(a)(2)(iv) Addressable
Audit controls 164.312(b) Standard
Mechanism to authenticate ePHI (integrity) 164.312(c)(2) Addressable
Person or entity authentication 164.312(d) Standard
Integrity controls (in transmission) 164.312(e)(2)(i) Addressable
Encryption (in transmission) 164.312(e)(2)(ii) Addressable

Encryption being addressable does not mean it can be skipped without thought. If you decide not to encrypt, the rule expects a documented reason and an equivalent alternative where reasonable and appropriate.

Business associate contracts (45 CFR 164.308(b) and 164.314)

Specification Reference Status
Written contract or other arrangement 164.308(b)(3) Required
Business associate contract terms 164.314(a)(2)(i) Required

A covered entity may let a business associate handle ePHI only with satisfactory assurances, documented in a written contract or other arrangement that meets 164.314(a). A business associate needs the same assurances from any subcontractor that handles ePHI on its behalf. For an MSP, that means a business associate agreement with each healthcare client and with any of your own suppliers that can reach client ePHI.

Policies, procedures and documentation (45 CFR 164.316)

Specification Reference Status
Policies and procedures 164.316(a) Standard
Time limit (retain for 6 years) 164.316(b)(2)(i) Required
Availability 164.316(b)(2)(ii) Required
Updates 164.316(b)(2)(iii) Required

Policies and any action, activity or assessment the rule requires to be documented must be kept in written form, which may be electronic. Keep that documentation for six years from the date it was created or last in effect, whichever is later, make it available to the people who implement the procedures, and review it periodically.

How to use the checklist

  1. Start with the risk analysis. The rest of the checklist is easier to answer once you know where ePHI lives and which risks matter. The HIPAA security risk assessment template walks through it.
  2. Answer each row with evidence. For every specification record what is in place, the evidence (policy, configuration, log, contract), the owner and the date checked.
  3. Decide each addressable item deliberately. Record whether you implemented it, implemented an alternative, or decided it is not reasonable and appropriate, and why.
  4. Turn gaps into a plan. Each gap becomes a risk management action with an owner and a date, and the results feed the periodic evaluation (164.308(a)(8)).
  5. Keep it current. Review when systems, suppliers or services change, not only on a fixed date.

Download the Word template

The HIPAA compliance checklist has one table per safeguard family with the reference, the required or addressable label, and columns for status, evidence, owner and date. It ends with an addressable-decisions log and a sign-off block. Replace every bracketed prompt and delete rows that do not apply, recording why.

Free editable Word file. Opens in Microsoft Word, Google Docs and LibreOffice.

Common mistakes

  • Treating addressable as optional. The rule requires an assessment and, where you do not implement, a documented reason and an equivalent alternative where reasonable and appropriate.
  • Ticking boxes without a risk analysis. The checklist shows what the rule asks for. The risk analysis shows which risks your safeguards need to address.
  • Forgetting business associate agreements with your own suppliers. Subcontractors that can reach ePHI need written assurances too.
  • Undated, unowned evidence. A checklist with no evidence, owner or date is hard to rely on later.
  • Losing old versions. Documentation must be kept for six years, so keep superseded versions of policies and assessments, not just the latest.

How this relates to NIST guidance

NIST SP 800-66 Rev. 2 is a resource guide for implementing the Security Rule. It maps each standard to practical activities and to the NIST Cybersecurity Framework, and it is useful when a client asks what “reasonable and appropriate” might look like in practice. NIST SP 800-30 Rev. 1 describes risk assessment methods that many teams use for the HIPAA risk analysis. The free HHS/ONC Security Risk Assessment Tool is aimed at small and medium providers. None of these replaces the regulation, which is the text this checklist follows.

Where GetCybr fits

GetCybr includes HIPAA in its framework catalogue, so an MSP or vCISO can track each Security Rule control, its evidence and its owner for every healthcare client in one place, alongside other frameworks such as NIST CSF and SOC 2. You can start with this Word checklist and move into the platform when spreadsheets and documents per client become hard to keep current.

Run the workflow across every client

GetCybr gives MSPs one workspace for assessments, evidence, roadmaps and client reporting.